Electrochemical Workstation ZENNIUM E
Electrochemical Workstation
Compact High Performance
The ZENNIUM E is a high-performance electrochemical workstation at a surprising affordable price. Besides a potentiostat / galvanostat it bears a frequency response analyzer unit (FRA) for promoting impedance spectroscopy. It provides high-end features like a frequency range up to 2 MHz, a max. current of ±2.0 A, a controlled voltage of ±12 V and an input impedance of 10 TΩ || 5 pF. The ZENNIUM E is a perfect workstation for a wide range of electrochemical applications with focus on corrosion, coatings and laminates.
It can be extended by a number of ZAHNER probes.
ZENNIUM E was developed using our 35 years of experience in producing high-precision electrochemical workstations and potentiostats / galvanostats of the high-end class. The ZENNIUM E is a revolution in the field of compact electrochemical workstations. Since it is equipped with a freqency response analyzer (FRA) unit on-board for the immediate promotion of impedance spectroscopy it can be seen as a unique tool for nearly all kinds of electrochemical measurements during the daily research routine. It provides a wide frequency range from 10 μHz to 2 MHz, an output current up to ±2.0 A and a fast signal processing. Special measurement techniques guarantee an ultra high accuracy and a minimal interference with the test object. The ZENNIUM E can be easily switched from grounded to floating operation.
ZENNIUM E comes bundled with the outstanding THALES Z 3 software package which offers all standard methods and more at a mouse click. This is why the Zennium E can easily be adapted to very different measurement requirements. Furthermore, with the probes available, the ZENNIUM E is able to grow with its tasks:
General |
|
Overall bandwidth |
DC - 2.5 MHz |
ADC resolution |
3 ADCs @ 18 bit |
Harmonic reject |
> 60 dB @ ½ full scale |
Potentiostat modes |
Potentiostatic, galvanostatic, pseudo-galvanostatic, rest potential, off, ZRA, FRA |
Cell connection |
2-, 3- ,4-terminal kelvin |
Floating / grounded |
Switchable |
Chassis |
Ground |
PC interface |
USB |
Dimensions |
255 x 160 x 385 mm |
Weight |
8 kg |
Accessories |
Cell cable set, USB cable, power cord, manual |
Power supply |
230/115/100VAC, 50/60Hz |
Ambient temperature, humidity |
+15 °C to +35 °C, < 50% without derating |
Frequency generator & analyzer |
|
Frequency range |
10 µHz to 2 MHz |
Accuracy |
< 0.0025% |
Resolution |
0.0025%, 10000 steps/decade |
Output potentiostatic |
||
Controlled voltage |
±4 V, ±12 V |
|
Resolution |
125 µV, 375 µV |
|
Accuracy |
±500 µV, ±2 mV / ±0.025% of set value |
|
Temperature stability |
better 20 µV / °C |
|
Compliance voltage |
±14 V |
Main |
AC amplitude |
1 mV to 1 V |
Main |
Bandwidth |
2 MHz @ 33 Ω load |
|
IR compensation |
auto AC impedance technique |
|
Small signal rise time |
250 ns to 200 µs in 5 steps, automatic selection by automatic stability control |
|
Slew rate |
15 MV/s |
|
Phase shift |
10° @ 250 kHz |
|
Output galvanostatic |
||
Full scale current ranges |
±100 nA to ±2.0 A in 10 steps, resolution 0.0031 % (16 bit) of range |
Main |
±1 nA to ±0.5 A in 12 steps, resolution 0.0031 % (16 bit) of range |
HiZ |
|
Accuracy ** |
±0.1 % of set value @ >|2 µA| to |100 mA| |
Main |
±1 % of set value, ±250 fA @ < |1 nA| |
HiZ |
Input |
||
Full scale potential ranges |
±1, ±2, ±4 V, ±12 V |
|
Potential resolution DC * |
0.0008 % / 32 µV (4 V range) |
|
Potential resolution AC * |
160 nV |
|
Potential accuracy DC ** |
±0.025 % of reading ±0.25 mV (4 V range) |
|
Offset temperature stability |
< 10 µV / °C |
|
Full scale current range * |
±100 pA to ±2.0 A in 33 ranges, |
Main |
Current accuracy DC ** |
±0.05 % of reading @ > |2 µA| to |100 mA| |
Main |
±0.5 % of reading, ±125 fA @ < |1 nA| |
HiZ |
|
Input bias current ** |
|±1 pA| (typ.) / |±5 pA| (max.) |
Main |
Current Resolution DC * |
2.5 pA |
Main |
Current Resolution AC * |
16 fA |
Main |
Input impedance |
10 TΩ || ±5 pF (typ.) |
Main |
Impedance range |
100 mΩ to 10 MΩ / 0.2% |
Main |
Common mode rejection |
> 86 dB @ 10 µHz to 100 kHz |
|
Input channel phase-tracking accuracy |
±0.1 ° @ 10 µHz to 100 kHz |
|
Equivalent effective input noise |
2 µV rms / 200 fA rms @ 1 mHz to 10 Hz |
Main |
* Garanteed by design. For details refer to application note "how to read specifications".
** In the first 6 months after factory calibration, after 20 min. of warm-up.
All ZENNIUM Electrochemical Workstations specifications PDF data sheet for download.
Download the latest information brochure about ZENNIUM E... b_zennium_e.pdf (PDF)
Download the latest information brochure about ZAHNER system...
catalog.pdf (PDF)
Download overview of hardware options and software modules...
HardwareSoftware.pdf (PDF)