Electrochemical Workstation ZENNIUM
The ZENNIUM is a modular electrochemical workstation including a potentiostat / galvanostat and a frequency response analyzer (FRA) unit with a frequency range up to 4 MHz at ±2.5 A and at a compliance voltage of ±14 V. With an input impedance of 1 TΩ || 5 pF the workstation is suitable for a wide range of electrochemical tasks.
The electrochemical measurement capabilites of the ZENNIUM workstation can be extented by adding up to four additional plug-in cards such as TEMP/U or EPC42. For example, the latter makes it possible to control up to four additional external devices such as power potentiostats of the PP/XPot-series (boosters) or electrical loads of the EL-series. Thus, our ZENNIUM electrochemical workstation is able to provide even more advanced measurement methods and allows us to satisfy any of your electrochemical research requirements.
ZENNIUM was developed using our 30 years of experience in producing high-precision electrochemical workstations of the high-end class. ZENNIUM provides a wider frequency range from 10 μHz to 4 MHz, an output current up to ±2.5 A and fast signal processing. Special measurement techniques guarantee an ultra high accuracy and a minimal interference with the test object.
ZENNIUM comes bundled with the outstanding THALES Z 3 software package which offers all standard methods and more at a mouse click. This is why the ZENNIUM can easily be adapted to very different measurement requirements. Furthermore, with the manifold options available, the ZENNIUM is able to grow with its tasks:
- Compliance Voltage up to ±120 V (CVB120)
- Output Power up to ±40 A / ±20 V (External Potentiostats)
- Input Impedance up to 1000 TΩ (HiZ Probe)
- Input Current up to 200 A (EL1000)
- 4 Additional Channels for True Parallel Impedance Spectra (PAD4)
General |
|
Overall bandwidth |
DC - 5 MHz |
ADC resolution |
18 bit |
Harmonic reject |
> 60 dB @ ½ full scale |
Potentiostat modes |
potentiostatic, galvanostatic, pseudo-galvanostatic, rest potential, off |
Cell connection |
2-, 3- ,4-terminal kelvin |
Chassis |
ground |
Extension slots |
4 |
PC interface |
USB 2.0 |
Dimensions |
364 x 160 x 376 mm |
Weight |
11.4 kg |
Accessories |
U-buffer, 2 cell cable set, USB cable, power cord, manual |
Power supply |
100/115/230VAC, 50/60Hz |
Ambient temperature |
+10 °C to +30 °C |
Ambient humidity |
< 60% without derating |
Frequency generator & analyzer |
|
Frequency range |
10 µHz to 4 MHz |
Accuracy |
< 0.0025% |
Resolution |
0.0025%, 10000 steps/decade |
Output potentiostatic |
||
Controlled voltage |
±4 V |
Main |
Resolution |
125 µV |
Main |
Accuracy |
±250 µV |
Main |
Temperature stability |
better 20 µV / °C |
|
Compliance voltage |
±14 V |
Main |
AC amplitude |
1 mV to 1 V |
|
Bandwidth |
4 MHz @ 33 Ω load |
|
IR compensation |
auto AC impedance technique |
|
Small signal rise time |
250 ns to 200 µs in 5 steps, |
automatic selection |
Slew rate |
15 MV/s |
|
Phase shift |
10° @ 250 kHz |
|
Output galvanostatic |
||
Controlled current |
±2.5 A |
|
Current range |
±100 nA to ±2.5 A in 10 steps |
Main |
Resolution min. |
0.025% |
|
Accuracy |
0.1% @ ≥ 2 µA to 100 mA |
Input |
||
Potential ranges |
±1, ±2, ±4 V |
Main |
Potential resolution |
256000 steps per range |
|
Offset voltage |
< 100 µV |
|
Offset temperature stability |
< 20 µV / °C |
|
Current range |
±100 pA to ±2.5 A in 30 steps, |
Main |
Accuracy |
0.05% @ ≥ 2 µA to 100 mA |
|
Input bias current |
10 pA |
Main |
Current resolution DC |
2.5 pA |
Main |
Current resolution AC |
16 aA |
HiZ Probe |
Input impedance |
1 TΩ || ±5 pF (typical) |
Main |
Impedance range |
1 mΩ to 1 GΩ / 2% |
Main |
Common mode rejection |
> 86 dB @ 10 µHz to 100 kHz |
|
Input channel phase-tracking accuracy |
±0.1 ° @ 10 µHz to 100 kHz |
|
Equivalent effective input noise |
2 µV rms / 200 fA rms @ 1 mHz to 10 Hz |
Main |
All ZENNIUM Electrochemical Workstations specifications PDF data sheet for download.
Catalog
Download the latest information brochure about ZAHNER system...
catalog.pdf (PDF)
Other Resources
Download overview of hardware options and software modules...
HardwareSoftware.pdf (PDF)